BRAND | Liebert |
Product | NXc80 |
Internal code | IMP3404907 |
Weight | 1 |
Technical specification | MANUFACTURER VERTIV Origin Italy Model LIEBERT NXc80 Nominal output 80kVA / 72kW Power factor 0,9 Parallel configuration 4 Phases Input / Output 3/3 Communication RS-232, SNMP-option INSERT DISTRIBUTOR Input voltage VAC 380/400/415 Input voltage range VAC 305 - 477 Rated frequency Hz 50/60 Frequency range Hz 40 - 70 Input power factor kW / kVA 0,99 Thrust distortion THDi at full linear load % <3 PERMANENT CHAIN Voltage VDC Nominal 384, (300 - 635) Number of battery cells in 1 string Max. 264, Minimum 180 Battery type VRLA OUTPUT INVERTER Voltage (three phase) VAC 380/400/415 Voltage tolerance at linear load% ± 1 Frequency Hz 50/60 Overloading 60 min. Continuous work 10 min. 125 1 min. 150 <200 ms%> 150 THDv voltage distortion at 100% linear load % 2 BIAPAS Voltage VAC 380/400/415 Voltage tolerance% + 20 / -40 Frequency Hz 50/60 Frequency Tolerance with Sync with inverter HZ ± 20 (± 10 selectable) EFFICIENCY AND HEAT LOSS Efficiency in normal mode (double conversion)% 95.7 Efficiency in ESO mode% 99.2 Heat losses at 100% (54kW) load kW 3.5 WORKING ENVIRONMENT Noise level at 1m (front) dBA ≤59 Altitude m ≤1500 Relative humidity% 0-95, no condensation Recommended working temperature of bat. o 15-15 ° C UPS storage and transport temperature -40 to +70 Recommended storage temperature batteries oC - 20 to 30 (20 ° C optimal) MECHANICAL CHARACTERISTICS Dimensions (WxHxD) VDC 600x1000x1600 Weight (without batteries) Kg 385 Degree of protection IP20 STANDARDS General safety requirements EN62040-1 / IEC62040-1 Electromagnetic Compatibility Requirements (EMC) EN62040-2 / IEC62040-2 (class C2) UPS classification according to VFI-SS-111 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Liebert - NXc80 number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Slovakia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Fan
FAN DC (2) 3610KL 04W-B
ups liebert
Closed Control 10.5kW R410.
External Baterry Cabinet
UPS distribution system
Battery pack of Emerson Network Power
Power 3000VA / 2700WattBridging time 5 min. At 100% loadUSB / IntellislotDauerwandler- (True Online) TechnologyDimensions: 88x602x430 (mm)Weight: 28kg
UPS battery 230VAC
Battery module 72V GXT3 Dimensions (WxDxH): 85x602x430 (2U) Weight: 42kg Up times at 100% load: without Batt.erw. 4 min. with a Batt.erw. 18 min. with two Batt.erw. 44 min. Three Batt.erw. 62 min. with four Batt.erw. 84 Min.
Efficient Direct Expansion Cooling for Data Centers
Uninterruptible Power Supply
HPAC Emerson Liebert‐Hiross, model PCW – PH045DC – precision cooling unit, chilled water version with Downflow – UP (Fan module is over the raised floor) air delivery. • Net Total Cooling Capacity TCC= 54,8 kW; • Net Sensible Cooling Capacity SCC= 44,9 kW;
POWER SUPPLY
UPS
Fan
UPS
On-Line UPS
Rack/tower UPS
APS Battery Module
USB / Intellislot
Kesintisiz Güç Kaynağı